P8. Abnormality in outdoor unit 1) Wrong wiring of indoor/outdoor connecting wire Mitsubishi Mr. Slim Error Codes - Membrane type remote controllers.
Mitsubishi Mr. Slim Error Codes - Membrane type remote controllers
Units should be installed by licensed contractor accordingly to local code require- ment. 3.4.. Connecting to Mr. SLIM air conditioner. (1) Standard 1:1.
As you can see, this has a long and slim vertical window cut into the front and can be used to show you An error occurred. Worldwide Android News 08/05/15 – Huawei P8, ZTE Blade S6 And More. May 8, 2015 2:05:30 PM MR show 91.
Главная · Оптовикам · Гарантия · Реквизиты · Полезно знать · Сервис · Контакты. В корзине: 0 товаров. Кулеры для воды. Кулеры напольные.
Mitsubishi Mr. Slim Error Codes - Membrane type remote controllers Check Diagnosis of malfunction Cause Check points code Signal transmitting/receiving During individual unit control 1) Check the transmission wire. EO error 1) Bad contact of transmission 2) Check with another remote controller. If “EO” is (Indoor controller does not wire still indicated, replace the indoor controller respond to remote controller 2) Signal transmitting/receiving cirboard. signal.) cuit is abnormal. If other check code appears. replace the original remote controller. P1 Abnormality of room temper- 1) Bad contact of thermistor ature thermistor (RT1) 2) Damaged thermistor 1) Check the thermistor. 2) Measure the resistance of the thermistor. Normal resistance should be as follows. 32°F····15kΩ 86°F·····4.3kΩ 50°F······9.6kΩ 104°F·····3.0kΩ 68°F······6.3kΩ If the resistance is normal, replace the indoor controller board. P2 Abnormality of indoor coil thermistor (RT2) P3 Signal transmission error (Remote controller does not respond to indoor controller signal.) 1) Bad contact of transmission 1) Check the transmission wire. wire 2) Check with another remote controller. 2) Signal transmitting/receiving cirIf “P3” is still indicated, replace the indoor cuit is abnormal. board. 3) Wrong operation due to noise If other check code appears, replace the origiwave emitted by other applinal remote controller. ances 3) Short-circuit between x and of CN40 and attach CN40 to the following units. q Second unit in twin control q Second and third units in triple control q Sub units in group control 1) Bad contact of transmission wire 2) Damaged thermistor 1) Check the connector. 2) Measure the resistance of the thermistor - . As for the normal resistance, refer to the case of P1. If the resistance is normal, replace the indoor controller board. P4 Abnormality of drain sensor P5 Malfunction of drain pump 1) Malfunction of drain pump 2) Damaged drain sensor 1) Check the drain pump. 2) q Check the drain sensor. q Check the drain sensor heater. Normal resistance should be 82Ω. If the resistance is normal, replace the indoor controller board. 1) 2) 3) 4) Clear obstructions from the air cycle. Clean the air filter Check the fan. Check the refrigerant temperature. Check the address-setting. Check with another remote controller. If check code other than “P7” appears, replace the original remote controller. Check SW6 setting. Check the indoor/outdoor connecting wire. Change the connection of electric wiring. Check the protection device. Measure the resistance of the outdoor coil thermistor. If the resistance is normal, replace the outdoor controller board. P6 Coil frost protection is working. 1) Short cycle of air cycle 2) Dirty air filter 3) Damaged fan 4) Abnormal refrigerant P7 System error 1) Wrong address-setting 1) 2) Signal transmitting/receiving cir- 2) cuit of remote controller is abnormal. 3) Wrong SW6-setting 3) 1) Wrong wiring of indoor/outdoor connecting wire 2) Reversed phase 3) Protection device is working 4) Damaged outdoor coil thermistor 1) 2) 3) 4) P8 Abnormality in outdoor unit
April 6, 2015 10:30:42 AM Super Slim Gionee Elife S7 Announced In India. Gionee has. Week 16 in review: Huawei P8, LG G4. April 19.